Conceptual
Login

Water Vapor Transmission Rate (WVTR) of Barrier Films

Water vapor transmission rate, or WVTR, tells you how fast water passes through a barrier. It is given in grams of water per square metre of film per day. A lower number means a better barrier. Plain food wrap lets through roughly one gram per square metre per day or more. Silicon modules cope with backsheets in about that range, because silicon does not mind a little water. Perovskite cells are far more fragile. Most reviews ask for about one ten-thousandth of a gram per square metre per day, or less, much like the films used for flexible organic screens. WVTR is not fixed. It rises steeply as the film gets hotter, so a value measured at room temperature can look far better than the film acts on a hot roof. Always check the test temperature and humidity next to the number. You can make a rough estimate with a calculator. Water in one year = WVTR × area × 365 days. For example, a film at 0.01 gram per square metre per day over 1 square metre lets in about 3.7 grams a year. That is enough water to ruin a thin perovskite layer many times over. After this Concept you can read a WVTR value, compare two barriers fairly, and estimate how much water reaches a cell in a year.